Español   English   

Fields of action

PHARMACY

  • Oral medicine.
  • Sterilised.
  • Biotechnological.
  • Veterinary medicine.
  • Research+Development.
  • Cosmetics.
  • Manufacturing of  "API s"
  • Active Pharmaceutical.
Tysein pastillas

BIOSECURITY

  • Research laboratories + Development.
  • Biological laboratories.
  • Chemical laboratories.
  • Effluents inactivation.
  • Bio waste.
Tysein laboratorio tubos

HOSPITAL

  • Operating rooms.
  • Pharmacy.
  • Hospital and rooms for the immunosupressed.
  • Infectious patients.
Tysein hospital

FOOD INDUSTRY

  • Thin laminate food packaging.
  • Sliced precooked dairy.
  • Meat and pastry product.
Tysein industria alimentaria fruta

SCIENTIFIC RESEARCH

  • Nanotechnology.
  • Biotechnology.
  • Animal farms.
  • Bio contamination.
Tysein investigación científica

TECHNOLOGICAL RESEARCH

  • Microelectronics.
  • Photovoltaic.
  • Aerospace.
  • Automation.
  • Opti.
Tysein investigación tecnológica


Engineering

The relevant Clean Rooms projects have been directed and implemented by our highly qualified personnel, with our know-how and experience in this type of installations.

All Rooms have been custom made "key in hand", from initial design to final certification, including:

  • Design of critical zones, clean or controlled contamination.
  • Civil buildings and room structure (parameters, ceilings, antistatic floors, etc) Clean Room Facilitie.Class 10.000.
  • Systems of climate control Client: ICMOL. Valencia University.
  • Systems of filtration.
  • Special fluids and processing fluids.
  • Auxiliary facilities such as steam, compressed air, gases, vacuum, etc.
  • Equipment such as contamination interlocks, thin laminates, isolation curtains, etc.
  • Supply and installation of plant machinery and auxiliary equipment.
  • Simulation of room contamination and recovery.
  • Validation and commissioning.
  • Implementation of management software.

Following our business strategy that is oriented to satisfy the needs of our clients, we strive to optimize technically and financially the resources to guarantee on-time delivery and high quality of our installations with the maximum environmental security.

Tysein ingeniería mapa

Tysein salas limpias

Infrastructure of clean rooms

We take care of the total construction of the clean rooms, from the design, based on the flows of people and products.
A good design is fundamental to maintain the commitments to achieve good containment and sterility.

The system of architecture used by TYSEIN incorporates the following characteristics:

  • Enclosures specially designed for clean zones or areas of bio-containment.
  • Based on a modular construction system, self-supporting for easy cleaning and decontamination, inorganic, impermeable to liquids and resistant to chemical agents that can be used for cleaning and decontamination.
  • Sandwich (laminated) panels for implementation of walls, finished in phenol resins and lacquered steel sheets or stainless steel and with polystyrene core, mesh of aluminium honeycomb , or rock wool.
  • The windows are perfectly levelled by both faces of the panel.
  • The door edgings and seals for closings have been designed with curved forms to avoid dust accumulation and for easy cleaning.
  • Watertight doors with draft excluder of inflatable closing seals for the areas of bio-containment BSL-3.
  • Removable ceilings of modular or continuous design that allow easy access to maintaining the installations.
  • Wide range of solutions, products, accessories and materials (sterile passage steps, interlocks, etc.).
  • Flexibility to adapt to the requirements and needs of the users.
Tysein infraestructura


Installation class 10.000 clean room – University of Valencia – Corpuscular Physics Institute

Type of Room: CLEAN

  • Class room: 10.000 according to standard USA FED-STD 209 D.
  • Useful room sizes: General space CLASS 10.000: 70,31 m2 .
  • Number of persons working: 11 persons .
  • Useful work surface per person: 7,29 m2 .
  • Height of room: 2,50 m. 
  • Process equipment: present.
  • Process equipment: present.
  • Safety clothing: full.
  • Thermal currents: no.
  •  Internal pressurization: 250 Pa.
  •  Air movement/hour: 30 to70 renewals/h.
  •  Entry-exit airlock: mandatory and class 100,000.
  •  Ceiling drive surface: 7,75 %.
  •  Air return: lower part of room.
  •  Filter quality and type:
    • 1st Stage: pre filter EU-3 - efficacy 35%.
    • 2nd Stage: bag filter type EU-8/9 - efficacy 95%.
    • 3rd Stage: absolute filter type EU-13/14- efficacy: 99,997%.
  • Airflow type: multidirectional.


Installation class 1000 Clean Room – University of Valencia – Gace – Group Astronomy and space science

Type of Room: CLEAN

  • Class Room: 1,000 according to standard: USA FED-STD 209 D.
  • Useful room sizes: General space CLASS 1,000: 38.29 m2.
  • Number of persons working: 4 persons.
  • Useful work surface per person: 9.57 m2.
  • Height of room: 2.85 m.
  • Process equipment: present.
  • Exit flow/hour: 2 persons.
  • Safety clothing: full.
  • Thermal currents: no.
  • Internal pressurization: 250 Pa.
  • Air movement/hour: 70 to 300 renewals/h.
  • Entry-exit airlock: mandatory and class 1,000.
  • Ceiling drive surface: 20% - 50%.
  • Air return: lower part of room.
  • Filter quality and type:
    • 1st Stage: EU-3 pre-filters - Efficacy 35%.
    • 2nd Stage: EU-8/9 type bag filters - Efficacy 95%.
    • 3rd Stage: EU-13/14 type absolute filters - Efficacy 99.997%.
  • Type of airflow: multidirectional.


Installation class 10.000 clean room – cyclotron room – Industrial Park Alboraya (Valencia)

Type of Room: CLEAN

  • Class Room: 1.000 according to standard USA FED-STD 209 D.
  • Useful room sizes: General space CLASS 1.000: 20,88 m2.
  • Number of persons working: 2 persons.
  • Useful work surface per person: 10,44 m2.
  • Height of room: 2,60 m.
  • Process equipment: present .
  • Exit flow/hour: 2 persons.
  • Safety clothing: full.
  • Thermal currents: no. 
  • Internal pressurization: 250 Pa. 
  • Air movement/hour: 30 to 70 renewals/h. 
  • Entry-exit airlock: mandatory and class 100.000. 
  • Ceiling drive surface: 6,56 %.
  • Air return: lower part of room.
  • Filter quality and type:
    • 1st Stage: EU-3 pre-filters - Efficacy  35%.
    • 2nd Stage: EU-8/9 type bag filters - Eficacia 95%.
    • 3er Stage: EU-13/14 type absolute filters -eficacia: 99,997%.
  • Type of airflow: multidirectional.


Installation class 10.000 clean room – University of Valencia – ICMOL – Institute of Molecular Science

Type of Room: CLEAN

  • Class Room: 10.000  according to standard USA FED-STD 209 D.
  • Useful room sizes: General space CLASS 10.000: 46,25 m2. 
  • Number of persons working: 3 persons.
  • Useful work surface per person: 13,64 m2. 
  • Height of room: 2,50 m. 
  • Process equipment: present. 
  • Exit flow/hour: 2 persons. 
  • Safety clothing: full.
  • Thermal currents: no. 
  • Internal pressurization: 25 Pa. 
  • Air movement/hour: 30 to 70 renewals/h.
  • Entry-exit airlock: mandatory.
  • Ceiling drive surface: 3,89 %.
  • Air return: lower part of room.
  • Filter quality and type:
    • 1st Stage: EU-3 pre-filters - efficacy 35%.
    • 2nd Stage: EU-8/9 type bag filters - efficacy 95%.
    • 3rd Stage: EU-13/14 type absolute filters - efficacy: 99,997%.
  • Type of airflow: multidirectional.


Class 10,000 cleanroom – University Hospital “Faith” – Research Centre – Unit Cell Therapy

Type of Room: CLEAN

  • Class of Room: 10,000 according to standard: USA FED-STD 209 D.
  • Useful room sizes: General space CLASS 10,000: 52.00 m2.
  • Number of persons working: 4 persons.
  • Useful work surface per person: 7.43 m2.
  • Height of room: 2.50 m.
  • Process equipment: present.
  • Exit flow/hour: 1 person.
  • Safety clothing: full.
  • Thermal currents: no.
  • Internal pressurization: >10 Pa.
  • Air movement/hour: 30 to 70 renewals/h.
  • Entry-exit airlock: mandatory.
  • Ceiling drive surface: 20% - 50%.
  • Air return: lower part of room.
  • Filter quality and type:
    • 1st Stage: EU-4 (G4).
    • 2nd Stage: EU-7 (F7).
    • 3rd Stage: EU-14 type absolute filters Efficacy 99.997%.
  • Type of airflow: multidirectional.

Tysein separador de espacios